DMU-03

DMG MORI DMU 50 (3rd Generation) · Siemens SINUMERIK ONE · Bay 1 · Cell C · s/n DMU50-24099

Live machine view
Five-axis cycle
X/Y/Z, the swivelling B trunnion and the C rotary table follow live telemetry; the door opens when the machine stops. Drag to rotate, scroll to zoom.
Cutting
Effectiveness
OEE this shift
Early (06:00–14:00) · 305 of 331 min running
72%

Availability

92.0%

Performance

79.5%

Quality

98.4%

Current job
WO-24114
Bracket, actuator · AD-3310-A

Pieces

31 / 40

Cycle time

4m 56s

This piece

1m 15s elapsed

Operator

Arden Adams

Tool

T11 · Ø8.5 drill

Tool life left

15%

Finishes

20 Oct 12:14

Losses
Downtime by reason
26.4 minutes lost this shift, biggest first.

Setup / first-off

10.2 min

Tool change

5.6 min

No material

4.2 min

Waiting QA

3.1 min

No operator

1.6 min

Breakdown

1.6 min

Quality
Pieces this shift
Ideal 228 s versus actual 287 s per piece.

Good

62

Scrap

1

Rework

0

OEE per hour · %

Queue
Jobs on this machine (3)
The job on the spindle and everything queued behind it, earliest due date first.

WO-24114

High

Helvetica Medtech · AD-3310-A OP10 · Al 7075-T6 · setup 112 min

Late

31/40 · due 20 Oct 07:30

WO-24115

Aerodyn Systems · NT-6650-A OP20 · Inconel 718 · setup 55 min

Queued

0/40 · due 22 Oct 02:30

WO-24116

Sandvik Tooling · ST-3390-A OP30 · H13 tool steel · setup 96 min

Queued

0/24 · due 22 Oct 21:30

Readings
Live telemetry
Polled every 5 seconds · spindle 18,506 h, service in 343 h

Spindle load

61 %

Spindle speed

8,738 rpm

Feed rate

1,544 mm/min

Spindle temp

46.9 °C

Coolant temp

26 °C

Coolant pressure

19.4 bar

Vibration

1.87 mm/s

Axis load B

25 %

Axis positions

X

153.6

Y

-38.4

Z

-172.9

B

-27.1

C

100.0

Spindle history
Spindle load, speed and vibration

Spindle load · %

Spindle speed · rpm

Vibration · mm/s

Alarms
Alarms (8)

Door interlock opened during cycle

Alarm 6621 · 10-20 10:17

high

B axis drive temperature high

Alarm 1105 · 10-20 09:27

medium

Tool life expired on T7, change required

Alarm 2019 · 10-20 09:05

low

B axis drive temperature high

Alarm 1105 · 10-19 15:36

medium

Tool life expired on T7, change required

Alarm 2019 · 10-19 09:31

high

Coolant level low in the tank

Alarm 7014 · 10-18 19:55

high

Coolant level low in the tank

Alarm 7014 · 10-18 19:08

high

Coolant level low in the tank

Alarm 7014 · 10-18 15:13

high